Angled Abutment (NON-HEX)

- Used for cement and screw-cement retained restoration to adjust prosthetic path at 15° and 25° axial angle
- Gold anodised for superior aesthetics and strength
- ! Unique One Prosthetic Platform - Any Abutment fits Any Implant Diameter
- ! Unique choice of 4 Cuff Diameters allows flexibility in prosthetic treatment planning –
o small cuff diameter can be placed on widest implant in Anterior Single Tooth Replacement to fit between narrow path of adjacent teeth
o wide cuff diameter can be used on smallest implant diameter in delayed implantation for molars to avoid huge cantilever
- Universal Hex Driver 1.2mm
- Recommended Tightening Torque: 30 Ncm
| NON-HEX 15 0 | ||||
|---|---|---|---|---|
| Cuff | 4.0 | 4.5 | 5.0 | 6.0 |
| 1 | ICHAA4001015N | ICHAA4501015N | ICHAA5001015N | ICHAA6001015N |
| 2 | ICHAA4002015N | ICHAA4502015N | ICHAA5002015N | ICHAA6002015N |
| 3 | ICHAA4003015N | ICHAA4503015N | ICHAA5003015N | ICHAA6003015N |
| 4 | ICHAA4004015N | ICHAA4504015N | ICHAA5004015N | ICHAA6004015N |
| 5 | ICHAA4005015N | ICHAA4505015N | ICHAA5005015N | ICHAA6005015N |
| 6 | ICHAA4006015N | ICHAA4506015N | ICHAA5006015N | ICHAA6006015N |
| NON-HEX 25 0 | ||||
|---|---|---|---|---|
| Cuff | 4.0 | 4.5 | 5.0 | 6.0 |
| 1 | ICHAA4001025N | ICHAA4501025N | ICHAA5001025N | ICHAA6001025N |
| 2 | ICHAA4002025N | ICHAA4502025N | ICHAA5002025N | ICHAA6002025N |
| 3 | ICHAA4003025N | ICHAA4503025N | ICHAA5003025N | ICHAA6003025N |
| 4 | ICHAA4004025N | ICHAA4504025N | ICHAA5004025N | ICHAA6004025N |
| 5 | ICHAA4005025N | ICHAA4505025N | ICHAA5005025N | ICHAA6005025N |
| 6 | ICHAA4006025N | ICHAA4506025N | ICHAA5006025N | ICHAA6006025N |
Milling Abutment (Hex and Non-Hex)

| HEX | ||||
|---|---|---|---|---|
| Cuff | 4.0 | 4.5 | 5.0 | 6.0 |
| 1.5 | ICHMHA40015 | ICHMHA45015 | ICHMHA50015 | ICHMHA60015 |
| 3 | ICHMHA40030 | ICHMHA45030 | ICHMHA50030 | ICHMHA60030 |
| NON-HEX | ||||
|---|---|---|---|---|
| Cuff | 4.0 | 4.5 | 5.0 | 6.0 |
| 1.5 | ICHMNA40015 | ICHMNA45015 | ICHMNA50015 | ICHMNA60015 |
| 3 | ICHMNA40030 | ICHMNA45030 | ICHMNA50030 | ICHMNA60030 |
- Used for cement and screw-cement retained restoration to adjust prosthetic path at 15° and 25° axial angle
- Gold anodised for superior aesthetics and strength
- ! Unique One Prosthetic Platform
- Any Abutment fits Any Implant Diameter
- ! Unique choice of 4 Cuff Diameters allows flexibility in prosthetic treatment planning
o small cuff diameter can be placed on widest implant in Anterior Single Tooth Replacement to fit between narrow path of adjacent teeth
o wide cuff diameter can be used on smallest implant diameter in delayed implantation for molars to avoid huge cantilever
- Universal Hex Driver 1.2mm
- Recommended Tightening Torque: 30 Ncm